Industrial Propane (C3H8) Gas Detector | Technical Product & Sourcing Guide

 

The industrial propane (C3H8) detector provides continuous real-time monitoring, threshold alarming, and signal transmission for combustible gas leaks. Designed for hazardous industrial and commercial environments, the unit detects propane concentrations from 0 to 100% LEL, triggering local audible-visual alarms and outputting relay contacts to shut down gas supply valves or activate ventilation fans.


Manufacturing Context: Produced in-house utilizing automated SMT surface-mount lines, CNC enclosure machining, and automated optical inspection (AOI) to ensure circuit stability. Each sensor module undergoes multi-point calibration using certified span gas prior to assembly.

 

 
  • Ultrasonic Propane Tank Level Detector
    •Bluetooth Low Energy (BLE) connectivity — real-time propane tank level monitoring right from your smartphone via the free TankIOT app. •Non-contact ultrasonic measurement technology — no...
 
Product Types
Fixed Wall-Mounted Detector
Integrated display, local buzzer/strobe, and direct relay outputs for standalone safety zones.
Split-Type Gas Transmitter
Separate sensor head and remote controller housing, designed for high-temperature or confined monitoring points.
Bus-Network Detector (RS485/Modbus)
Multi-point networking capability engineered for large plant DCS integration.

 

Key Specifications

Parameter

Specification

Target Gas

Propane (C3H8)

Detection Range

0 to 100% LEL

Sensor Technology

Catalytic Combustion (Standard) / Infrared (Optional for inert/high-concentration environments)

Response Time

T90 < 15 seconds

Accuracy

±3% F.S.

Signal Output

4–20mA analog, RS485 (Modbus RTU)

Relay Output

2 sets of Form C dry contacts (Alarm 1, Alarm 2; 250VAC/3A)

Power Supply

24VDC (±20%)

Ingress Protection

IP65 / IP66 (Cast aluminum enclosure)

Explosion-Proof Rating

Ex db IIC T6 Gb / Class I, Division 1 (Optional)

Functional Safety

SIL2 Certified (IEC 61508)

Operating Temperature

-40°C to +70°C

 

Ultrasonic Propane Tank Level Detector

 

Applications

LPG Storage & Filling Plants: Monitoring compressor houses, filling sheds, and tank perimeters.


Gas Equipment Skids & Regulating Stations: Early leakage detection on valve manifolds and vaporization units.


Industrial Manufacturing Plants: Combustible gas monitoring near industrial furnaces, boilers, and fuel lines.


Commercial Kitchens & Restaurants: High-density baseline monitoring tied to automatic emergency shut-off valves.

 

Customization & Integration
 

Physical Installation

Direct wall mounting, pipe/pole mounting brackets, or duct-mount sampling probes.

System Integration

Seamless connection to third-party PLCs, DCS, and fire alarm control panels via 4-20mA current loops or Modbus RTU protocol.

Enclosure & Branding

Custom laser-etched nameplates, OEM housing colors, and proprietary firmware branding for bulk orders.

Relay Logic

Factory-programmable latching or non-latching alarm states, adjustable low/high alarm thresholds.

 

Quality & Compliance

Sensor Calibration

Calibrated using certified NIST-traceable propane-air mixtures on automated test benches.

Burn-in Testing

72-hour continuous power-on aging test conducted on 100% of finished circuit boards.

Certifications

CE, RoHS compliant; explosion-proof models certified to ATEX / IECEx; functional safety evaluated to SIL2.

 

 

Frequently Asked Questions

 

Q: What is the standard service life of the catalytic sensor?

A: Under normal operating conditions (clean air, minimal silicone/sulfur exposure), the catalytic sensor lasts 3 to 5 years. Periodic calibration every 6 months is recommended.

Q: Can this detector operate in sub-zero outdoor conditions?

A: Yes. The standard operating temperature range is -40°C to +70°C. For outdoor installations prone to heavy condensation or rain, the IP66 rain-shield accessory is recommended.

Q: What is the difference between Catalytic and Infrared sensors for propane?

A: Catalytic sensors require oxygen and are cost-effective for general ambient monitoring. Infrared (NDIR) sensors do not require oxygen, resist poisoning from chemical contaminants, and suit inert or high-concentration gas streams.

Q: How many detectors can be linked to a single control panel?

A: Using RS485 Modbus RTU communication, up to 64 detectors can be daisy-chained to a single monitoring hub or PLC master port.

Q: What is your minimum order quantity (MOQ) for custom OEM labeling?

A: The standard MOQ for private-label silk-screening and customized manuals is 50 units per batch. Sample units are available for technical evaluation.

Q: What documentation is provided with bulk shipments?

A: Each shipment includes individual factory calibration certificates, material test reports (MTR) for enclosures, wiring diagrams, and compliance certificates.

 

modular-1
Request a Quote

To receive a formal quotation within 24 hours, please provide the following project details:
Model Type: Fixed wall-mounted / Split-type / Bus-network
Quantity Required: Prototype / Pilot batch / Volume order
Sensor Preference: Catalytic / Infrared
Explosion-Proof / SIL Requirement: e.g., ATEX Ex db IIC T6 / SIL2
Destination Port / Delivery Location:
Specific Integration Requirements: Custom Modbus registers, specific enclosure coating, etc.

As one of the most experienced propane detector suppliers in China, we're featured by quality products and low price. Please feel free to buy discount propane detector made in China here from our factory. Welcome to view our website for more information.

industrial propane leak detector, propane gas detection device, propane gas detector with modbus
Send Inquiry