Level Sensor, Optical, Version 2

Aug 02, 2026

Leave a message

Level Sensor, Optical, Version 2: The Complete Guide

In this guide: What "Level Sensor, Optical, Version 2" means as a 2nd-generation point-level sensor, the verified infrared total-internal-reflection principle, representative Version-2 specifications, what typically changes from V1 to V2, why optical beats float/conductive alternatives, integration with PLC/MCU, installation, comparison, and the complete FAQ.


Level Sensor, Optical, Version 2: Quick Answer

A "Level Sensor, Optical, Version 2" is a second-generation optical (infrared total-internal-reflection) point-level liquid sensor - a sealed solid-state switch that detects liquid at one height by an IR LED and phototransistor optically coupled through a precision tip: in air the infrared is guided back to the phototransistor (no liquid), and when the tip is immersed the light escapes and the output changes state (liquid present). "Version 2" denotes a product revision of the optical level sensor: typical V2 upgrades over a first generation are a wider temperature range, smaller housing, a smarter output ASIC (hysteresis, diagnostics), optional IO-Link, better chemical resistance, and lower power - while the core optics (IR TIR, any-liquid detection) stay the same. Representative V2 class values (drawn from the verified Optomax-family optical level sensors) are 8–30 V DC, ~7.5 mA, NPN/PNP output up to ~1 A, −25 to +80 °C (extended −40 to +125 °C), M12×1 threaded Polysulfone/glass tip, IP67–68 sealing, millisecond response, and 850–950 nm infrared. Confirm the exact V2 variant parameters against the manufacturer's datasheet (see disclaimer).


What "Version 2" Means

A Product Revision, Not a New Principle

V1 → V2 typically changes:

Aspect V1 V2 (typical)
Temperature Narrower Wider / extended
Housing Larger Smaller
ASIC Basic Hysteresis + diagnostics
Interface Switch only Optional IO-Link
Materials Standard Better chemical resist
Power Higher Lower

Same optics, better package: Version 2 keeps the sealed infrared TIR optics that define an optical level sensor, but refines the surrounding electronics and mechanical package. You get the same "no moving parts, detects almost any liquid" behavior with a more capable output stage, broader operating window, and often a digital interface for diagnostics. The principle does not change between versions - the sensor still decides "liquid present / absent" by whether the IR light returns to the phototransistor.


Operating Principle (Verified)

Infrared Coupling at a Sealed Tip

The verified optical mechanism:

State Light Path Phototransistor Output
Dry (air) Tip guides light back Illuminated No liquid
Wet (liquid) Light escapes tip Darkened Liquid present

Verified from the Optomax family: Optical level sensors "contain only an infra-red LED and phototransistor which are optically coupled by the tip when the sensor is in air. When the sensing tip is immersed in liquid, the infra-red light escapes making the phototransistor output change state." The sensor "can detect the presence or absence of almost any liquid type, oil or water based." This total-internal-reflection principle is why one optical tip sees both oil- and water-based liquids - by refractive index, not conductivity - and is identical across V1 and V2. (For the refractive math, see What Are Optical Sensors.)


Representative Version-2 Specifications

Class Values (Confirm vs. Datasheet)

Typical V2 optical level sensor values:

Parameter V2 Class Value
Principle IR LED + phototransistor, TIR tip
Supply 8–30 V DC
Current ~7.5 mA max (at 30 V)
Output NPN / PNP, sink/source up to ~1 A
Response Millisecond (< 1 ms typical)
Tip material Polysulfone (PP/PSU) or glass
Temperature −25 to +80 °C (ext. −40 to +125 °C)
Mount M12 × 1 threaded
Ingress IP67–68
Wavelength 850–950 nm (IR)

Read the datasheet for exact numbers: These are representative Optomax-family / optical-level-sensor class values, not a confirmed extract from one specific "Version 2" datasheet. The 8–30 V supply, ~7.5 mA, 1 A sink/source, −25 to +80 °C, M12×1, and IP67–68 figures are established for the verified Optomax Industrial Series (e.g., LLC200D324-003); confirm your exact V2 variant's supply scheme, output rating, and temperature before design.


V1 vs. V2 - What Typically Changes

The Revision Improvements

Improvement Why It Matters
Wider temp range Hot/clean-in-place, cold duty
Smaller housing Fits tight manifolds
Smart ASIC Hysteresis stops chatter
Diagnostics Detect fouled/blocked tip
IO-Link Remote param + status
Lower power Battery / low-power loops
Better seals Longer chemical life

The practical V2 gains: A V2 optical level sensor usually adds an ASIC with built-in hysteresis (so the output does not chatter at the trip point), diagnostic capability (tip fouling or blocked can be flagged), and sometimes IO-Link for remote configuration and status. A wider temperature range and better sealing extend duty into hot, clean-in-place, or chemically aggressive service, and a smaller body fits compact manifolds. None of this changes the optical decision - it makes the sensor easier to integrate and maintain.


Why Optical

Versus Float and Conductive

Optical vs. the alternatives:

Method Moving Parts Any Liquid Sealed Conductive?
Optical (V2) No Yes (oil/water) Yes No (refractive)
Float Yes (pivot/reed) Yes No (mech) No
Conductive No Conductive only Depends Yes (required)
Capacitive No Yes Yes No

Why pick optical: Optical has no moving parts (unlike a float switch, which can stick or wear), detects any liquid by refractive index (unlike a conductive probe, which needs a conductive liquid and fails on pure water), and is sealed at the tip (no mechanical interface to leak or jam). Capacitive is the other sealed, any-liquid option, but optical is the simpler point-level switch with the fastest response and no calibration drift. For a single on/off liquid point, optical (V2) is often the cleanest choice.


Integration with PLC / MCU

Wiring the Output

NPN vs. PNP for V2:

Output Wiring Read State
NPN (sink) Pull-up to V+; OUT to GND when wet Wet = LOW
PNP (source) Pull-down to GND; OUT to V+ when wet Wet = HIGH

Same rule as the OS family: An optical V2 sensor with an NPN (sink) output needs a pull-up resistor to V+ and reads LOW when wet; a PNP (source) output needs a pull-down and reads HIGH when wet. Share ground between sensor and controller, confirm the supply (8–30 V class), and if the V2 variant offers IO-Link, use it to set the trip hysteresis and read diagnostics remotely. The logic is identical to the Optomax OS-series optical sensors (OS-1 / OS2 / OS3 / OS4). (For real firmware examples, see Optical Level Sensor with Arduino / OS2 Digital Implementation.)


Installation & Best Practices

Getting a Clean Trip

Step Action
1. Confirm supply 8–30 V class (or per datasheet)
2. Bias output Pull-up (NPN) / pull-down (PNP)
3. Share ground Sensor ↔ controller
4. Mount orientation Tip wetted as intended
5. Keep tip clean Fouling blinds the optic
6. Avoid air bubble Trapped bubble mimics dry
7. Use hysteresis V2 ASIC stops chatter
8. Full-speed validate At line rate

V2 makes this easier: Because V2 typically adds hysteresis and diagnostics in the ASIC, installation is more forgiving - the output will not chatter at the trip point, and a fouled tip can be flagged instead of silently failing. Still keep the tip clean and wetted, avoid a trapped air bubble (it reads as dry), and validate at full operating speed.


Comparison to Other Level Methods

Quick Decision

If you need… Pick
Single on/off point, any liquid Optical (V2)
No moving parts + sealed Optical or capacitive
Conductive liquid only Conductive
Continuous 0–100% Ultrasonic / radar / capacitive / pressure
Low cost, simple Float (accept wear)
Through non-metal wall Capacitive

Applications

Where Optical V2 Fits

Application Why V2
Tank high/low alarm Simple on/off
Pump dry-run protection Wet/dry trip
Appliances (dishwasher, ice) Sealed, small
Oil/water-based liquids Any-liquid tip
Hot/clean-in-place Wider temp (V2)
Compact manifolds Smaller housing (V2)

Frequently Asked Questions

Q1: What is a "Level Sensor, Optical, Version 2"?

A "Level Sensor, Optical, Version 2" is a second-generation optical point-level liquid sensor - a sealed solid-state switch that detects liquid at one height using an infrared LED and phototransistor optically coupled through a precision tip. In air, the IR is guided back to the phototransistor (output reads "no liquid"); when the tip is immersed, the light escapes and the output changes state ("liquid present"). "Version 2" is a product revision: the optics are unchanged, but V2 typically adds a wider temperature range, smaller housing, a smarter output ASIC (hysteresis + diagnostics), optional IO-Link, better chemical resistance, and lower power. Representative V2 class values are 8–30 V DC, ~7.5 mA, NPN/PNP up to ~1 A, −25 to +80 °C, M12×1, IP67–68 - confirm exact parameters against the datasheet.

Q2: How does an optical level sensor detect liquid with no moving parts?

An optical level sensor has no moving parts because detection is purely optical. Inside the sealed tip, an IR LED and a phototransistor are optically coupled: in air, the tip's geometry guides the IR from the LED to the phototransistor (output = no liquid); when liquid wets the tip, the liquid's refractive index bends the IR out of the tip so it no longer reaches the phototransistor, and the output changes state (liquid present). This is the verified Optomax mechanism - "only an infra-red LED and phototransistor optically coupled by the tip… when immersed, the infra-red light escapes making the phototransistor output change state." Nothing moves; the light path simply changes with the medium. That is why the sensor is sealed, fast (millisecond), and long-lived.

Q3: What liquids can an optical (V2) level sensor detect?

An optical V2 sensor detects the presence or absence of almost any liquid - both oil-based and water-based - because it triggers on the refractive-index step at the tip, not on conductivity or color. Water (n ≈ 1.33) and oil (n ≈ 1.46) both refract the IR out of the tip; even dyed or opaque liquids work, and pure (non-conductive) water is detected where a conductive probe would fail. The requirement is that the liquid wets the tip and does not leave a coating that defeats the optic. Confirm the tip material's chemical compatibility (Polysulfone/PP/PSU or glass) against your liquid in the datasheet before use - V2's better seals and materials extend chemical duty.

Q4: What is the difference between Version 1 and Version 2 of an optical level sensor?

Version 2 keeps the same infrared total-internal-reflection optics as Version 1 but refines the electronics and package. Typical V2 upgrades are a wider temperature range, a smaller housing, a smarter output ASIC with built-in hysteresis (no chatter at the trip point) and diagnostics (tip fouling/blocked flagged), optional IO-Link for remote config and status, lower power, and better chemical-resistant seals. The core decision - liquid present/absent by IR coupling - is identical. So V2 is easier to integrate and maintain: you get the same sealed, any-liquid, millisecond point detection with a more capable output stage and a broader operating window. The "version" is the revision, not a new sensing principle.

Q5: How do I wire an optical V2 level sensor to a PLC?

Wire it by output type. For an NPN (sink) V2 output, connect V+ and GND to the 8–30 V supply, add a pull-up resistor from OUT to V+, and the PLC input reads LOW when the tip is wet (liquid present). For a PNP (source) output, add a pull-down from OUT to GND, and the PLC reads HIGH when wet. Share ground between sensor and PLC, confirm the supply voltage, and if the V2 variant offers IO-Link, use it to set trip hysteresis and read diagnostics over the digital link instead of discrete wiring. The logic matches the Optomax OS-series optical sensors (OS-1 / OS2 / OS3 / OS4). Keep the tip clean and wetted, avoid a trapped air bubble, and validate at full line speed.


The Bottom Line

A "Level Sensor, Optical, Version 2" is a second-generation optical (infrared total-internal-reflection) point-level liquid sensor - a sealed solid-state switch that detects liquid at one height by an IR LED and phototransistor coupled through a precision tip: in air the IR returns to the phototransistor (no liquid), and when immersed the light escapes and the output changes state (liquid present). "Version 2" is a product revision: the optics are unchanged, but V2 typically adds a wider temperature range, smaller housing, a smarter output ASIC (hysteresis + diagnostics), optional IO-Link, better chemical resistance, and lower power. Representative V2 class values (Optomax-family based) are 8–30 V DC, ~7.5 mA, NPN/PNP up to ~1 A, −25 to +80 °C (extended −40 to +125 °C), M12×1 threaded Polysulfone/glass tip, IP67–68, millisecond response, 850–950 nm IR. Optical beats a float switch (no moving parts, sealed) and a conductive probe (any liquid, including pure water, by refractive index, not conductivity); capacitive is the other sealed any-liquid option but optical is the simpler, faster point switch. Wire NPN with a pull-up (wet = LOW) or PNP with a pull-down (wet = HIGH), share ground, use the V2 hysteresis to avoid chatter, and confirm exact parameters against the manufacturer's datasheet.


Last updated: August 2026

Disclaimer: This guide describes a "Level Sensor, Optical, Version 2" as a generic class of second-generation optical (infrared total-internal-reflection) point-level liquid sensors. The operating principle is verified against the established Optomax-family optical level sensors (SST Sensing / Process Sensing Technologies) - e.g., the Optomax Industrial Series part LLC200D324-003 (8–30 V DC, 7.5 mA max, 1 A sink/source, −25 to +80 °C) and the Optomax Basic Series LLC200A3SH - and the quoted mechanism ("only an infra-red LED and phototransistor optically coupled by the tip… when immersed, the infra-red light escapes") is drawn from those datasheet descriptions. The specific "Version 2" designation and its exact supply scheme, output rating, temperature, materials, and IO-Link support could not be pinned to a single public datasheet entry and are presented as representative optical-level-sensor class values. For procurement or design, confirm the exact V2 variant parameters against the official manufacturer datasheet. This guide is not affiliated with, endorsed by, or sponsored by any sensor manufacturer or distributor.

Send Inquiry