Solid-State Level Switches: Allen-Bradley
Allen-Bradley solid-state level switches are the non-mechanical level detection switches in the Allen-Bradley portfolio - including capacitive level switches (series 871A), conductive level switches (series 832), and optical level switches used in photoelectric sensor applications (series 42EF) - that detect liquid or material level without a moving float, using an electronic or optical property to sense the presence of the target medium. The article covers: what "solid-state" means in the context of Allen-Bradley level switches (the distinction from mechanical float switches), the three Allen-Bradley solid-state level switch families (capacitive, conductive, and optical), the key specifications that define performance (sensitivity adjustment, output type, voltage, material, and certification), the four key advantages over mechanical float switches (no moving parts, faster response, resistance to coating liquids, and compact size), the five main application areas (industrial process, food and beverage, chemical storage, HVAC, and power generation), the four common mistakes when selecting solid-state level switches, and the five factors for matching the right Allen-Bradley solid-state level switch to the application.
Solid-State Level Switches: Allen-Bradley - Quick Answer
Allen-Bradley solid-state level switches include three main product families - the 871A capacitive level switch (detects level through non-metallic tank walls by measuring capacitance change), the 832 series conductive level switch (detects conductive liquid level by measuring current between electrodes), and the 42EF PhotoSwitch series applied to optical level detection (detects liquid presence at a prism tip by changes in total internal reflection) - all sharing the solid-state characteristic of no moving float or mechanical contact to wear out. The key advantage over a mechanical float switch is reliability: without a moving float, there is no stem to jam in coating liquids, no magnetic contacts to corrode, and no buoyancy failure at an angle. Allen-Bradley solid-state level switches are priced above float switches but below continuous level transmitters, making them the cost-effective solution for point-level detection in demanding applications. The selection rule: capacitive for non-metallic tanks and through-wall detection; conductive for conductive liquids (water, aqueous solutions) in metallic or grounded tanks; optical for clean liquids in sanitary applications. The mechanical float switch (series 840, 841) remains the correct choice for simple open-tank applications where the liquid is not coating and cost is the primary driver. (The Allen-Bradley brand overview: Sensors and Switches: Allen-Bradley; the level switch guide: The Ultimate Guide to Liquid Level Switches; the capacitive sensors: Capacitive Level Sensors Explained.)
What Does "Solid-State" Mean for Allen-Bradley Level Switches?
The Core Distinction - No Moving Float, No Mechanical Contact
The solid-state vs mechanical comparison table (Featured Snippet):
| Feature | Allen-Bradley solid-state level switch | Allen-Bradley mechanical float switch (series 840/841) |
|---|---|---|
| Sensing principle | Electronic or optical - measures a property of the liquid (capacitance, conductivity, or light reflection) | Mechanical - a float physically rises and falls with the liquid surface |
| Moving parts | None in the sensing element | The float, the stem, and the magnetic contacts move with every level change |
| Liquid contact | Electrodes, prism, or antenna - all fixed | The float body and the stem are immersed in the liquid |
| Coating resistance | High (capacitive and optical are affected; conductive is not) | Low - coating liquids stick to the float and stem and cause jamming |
| Response time | Fast (milliseconds to seconds) | Slower (depends on float speed and liquid turbulence) |
| Installation | Through a tank wall (capacitive) or with a small process connection | Requires a tank penetration large enough for the float and stem |
| Tank size | Any size - the sensor size does not scale with tank size | Larger tanks require larger floats and longer stems |
| Orientation sensitivity | Low - no orientation requirements | High - the float must be able to move freely in the liquid |
| Price range | $30–$200 | $50–$150 |
| Best for | Coating liquids, small tanks, through-wall detection, sanitary applications, sealed tanks | Simple open-tank water applications with non-coating liquids and ample installation space |
"Solid-state" for Allen-Bradley level switches means the level is detected by measuring an electrical or optical property of the liquid or the tank environment - capacitance between electrodes, current flow through the liquid, or changes in light reflection - without a buoyant float that physically moves with the liquid surface: A mechanical float switch (series 840, 841) uses a buoyant element that physically rises as the liquid rises, driving a magnet that closes contacts at the set point. This is a proven, reliable principle - but it has three fundamental limitations. First, the float and stem are immersed in the liquid: if the liquid coats, the stem sticks and the switch fails. Second, the float requires vertical travel space: it cannot be used in small tanks, in tanks with internal obstructions, or in horizontal mounting configurations. Third, the switch contact is mechanical: it can arc, pit, and eventually fail after millions of switching cycles. A solid-state level switch avoids all three limitations. The sensing element is fixed - there is nothing to jam, nothing to corrode, and nothing that wears out from mechanical cycling. The switch detects the presence of the liquid by measuring an electronic property: the capacitance between two electrodes changes as liquid replaces air between them; the current through two electrodes changes as conductive liquid bridges the gap; the total internal reflection at a prism tip changes as liquid covers the prism. None of these require a moving part. The Allen-Bradley solid-state level switch is not a replacement for the float switch in all applications - for a simple open water tank with no coating risk and ample installation space, the mechanical float switch (series 840) is still the right choice. But for any demanding application, the solid-state switch is the reliable, long-life solution. (The level switch guide: The Ultimate Guide to Liquid Level Switches; the float switch comparison: Choosing the Right Level Switch; the capacitive: Capacitive Level Sensors Explained.)
The Three Allen-Bradley Solid-State Level Switch Families
871A Capacitive, 832 Conductive, and 42EF PhotoSwitch Optical
The three solid-state families table (Featured Snippet):
| Family | Series | Technology | Best for | Avoid when |
|---|---|---|---|---|
| Capacitive | 871A | Measures capacitance change between two electrodes | Non-metallic tanks, through-wall detection, solids and granules, sealed tanks | Conductive liquids (short the capacitance measurement) |
| Conductive | 832 | Measures current between electrodes immersed in the liquid | Conductive liquids (water, aqueous solutions, mild chemicals) in grounded tanks | Non-conductive liquids (oils, solvents, hydrocarbons) |
| Optical (PhotoSwitch) | 42EF | Detects liquid at a prism tip by total internal reflection change | Clean liquids in sanitary applications, small tanks, fast response | Coating liquids, foam, liquids that leave residue on the prism |
The three Allen-Bradley solid-state level switch families - capacitive (871A), conductive (832), and optical (42EF PhotoSwitch) - each serve a distinct application domain defined by the liquid's electrical properties and the tank's material: Capacitive level switch (series 871A): the 871A uses two electrodes mounted inside the sensor body. As the liquid level rises and falls, the dielectric between the electrodes changes (liquid replaces air), changing the capacitance. The sensor electronics detect this change and switch the output. The key advantage of the 871A is through-wall detection: because the electrodes measure capacitance through the tank wall, the sensor can be mounted on the outside of a non-metallic tank (plastic, glass, composite) without penetrating the tank. This is the only solid-state option for sealed non-metallic tanks where no penetration is desired. The 871A detects both liquids and solids (powders, granules) because both change the dielectric constant between the electrodes. It fails in conductive liquids - the electrical current flows between the electrodes through the conductive liquid, shorting the capacitance measurement. The sensitivity of the 871A is adjustable (using a trimmer on the sensor body), which allows the sensor to be tuned for the specific dielectric constant of the liquid. Typical sensing distance (electrode gap): 5–25 mm. Body sizes: M18 and M30 cylindrical. Wetted materials: polypropylene (standard) and PTFE (for aggressive chemicals). Temperature rating: typically –25°C to +70°C. Conductive level switch (series 832): the 832 series uses two or more electrodes immersed in the liquid. A low-voltage AC current is applied between the electrodes. When the liquid covers the electrodes, the circuit is completed and current flows - the sensor detects this and switches the output. The 832 is the simplest and lowest-cost solid-state level switch for conductive liquids. It is designed for use in grounded metallic tanks or in tanks where a ground reference (a tank wall electrode or a separate ground rod) is available. Multi-point level detection is possible: a single 832 controller can manage multiple electrode pairs at different heights, providing multiple switch points from one controller. The limitations: the 832 only works in conductive liquids (water, aqueous solutions, mild acids and bases). It cannot detect non-conductive liquids (oils, solvents, hydrocarbons). The electrodes must be immersed in the liquid, so tank penetration is required. Electrode fouling (from scaling, corrosion, or coating) can cause false readings. Optical level switch (series 42EF PhotoSwitch applied to level detection): the 42EF PhotoSwitch, primarily known as a photoelectric sensor for presence detection, is applied to level detection using a prism tip that is immersed in the liquid. When liquid covers the prism tip, the total internal reflection (TIR) of the infrared LED changes - liquid has a different refractive index than air - and the sensor output changes state. The 42EF for level detection is used in sanitary applications (food, pharmaceutical, beverage) where the glass or sapphire prism is chemically compatible and can be cleaned in place (CIP). The response time is the fastest of the three families (1–10 ms). The limitations: the prism must be immersed, coating liquids block the TIR, and the sensor is sensitive to bubbles and foam.
Key Specifications for Allen-Bradley Solid-State Level Switches
Sensitivity, Output Type, Voltage, Material, and Certification
The key specifications table (Featured Snippet):
| Specification | 871A Capacitive | 832 Conductive | 42EF Optical |
|---|---|---|---|
| Sensing principle | Capacitance change between electrodes | Conductivity between electrodes in liquid | Total internal reflection change at prism tip |
| Target media | Liquids and solids; non-conductive liquids | Conductive liquids only (water, aqueous) | Clean liquids; avoid coating liquids |
| Tank material | Non-metallic (for through-wall); metallic (with electrode insertion) | Metallic (grounded) or with ground reference | Any - prism tip is immersed |
| Process connection | M18/M30 threaded or custom bracket | Threaded rod electrodes (customer-cut to length) | M18/M30 threaded or sanitary clamp |
| Sensitivity adjustment | Yes - onboard trimmer (adjustable for liquid dielectric) | No - set by electrode spacing and controller sensitivity | No - fixed set point |
| Supply voltage | 10–30 VDC or 24–240 VAC/DC (varies by model) | 24–240 VAC/DC | 10–30 VDC |
| Output type | PNP, NPN, or relay | Relay contact output | PNP or NPN |
| Wetted material | Polypropylene or PTFE | 316 stainless steel electrodes; PVC or PTFE insulation | Glass or sapphire prism; 316SS housing |
| Temperature rating | –25°C to +70°C | –10°C to +80°C | –25°C to +85°C |
| Enclosure rating | IP67 | IP65 | IP67 or IP69K (sanitary models) |
| Certification available | ATEX/IECEx for hazardous areas | - | 3-A sanitary, IP69K washdown |
The five key specifications for Allen-Bradley solid-state level switches - sensitivity, output type, voltage, material, and certification - must be verified against the application in this order: the liquid's electrical properties first (conductive or non-conductive), then the tank material and process connection, then the output type, then the environment (temperature, washdown, hazardous area), and finally the certification: Sensitivity: the capacitive 871A has an onboard sensitivity adjustment (a trimmer or a programming mode) that tunes the sensor for the specific dielectric constant of the liquid. Water has a high dielectric constant (approximately 80); oil has a low dielectric constant (approximately 2–3). The sensitivity adjustment allows the 871A to work in both. Without adjustment, a sensor calibrated for water will not detect oil, and a sensor calibrated for oil will be oversensitive in water. Always verify that the sensitivity range of the 871A covers the dielectric constant of the target liquid. Output type: the 871A and 42EF use solid-state outputs (PNP or NPN), which are compatible with standard 24 VDC PLC inputs. The 832 uses a relay contact output, which can switch AC or DC loads directly (up to 5 A) without a PLC input interface. Relay outputs are more robust than solid-state outputs - they are immune to overvoltage and can switch inductive loads - but they have a limited mechanical life (typically 10⁶ operations) compared to solid-state outputs (no mechanical limit). Voltage: verify the supply voltage range matches the installation. Most 871A models are 10–30 VDC. Some 832 controllers are 24–240 VAC/DC. The 42EF is 10–30 VDC. Material: the wetted material must be chemically compatible with the liquid. Polypropylene is standard for the 871A in water and mild chemicals. PTFE is used for aggressive chemicals. 316 stainless steel electrodes are standard for the 832. Glass or sapphire prisms are used for the 42EF optical level switch. Always verify chemical compatibility with the safety data sheet (SDS) for the liquid. Certification: hazardous area certification (ATEX/IECEx) is available for the 871A capacitive switch in models designated for gas and dust environments. The 42EF optical switch is available with 3-A sanitary certification and IP69K washdown rating for food and beverage applications. Specify the certification before selecting the model - not after. (The output matching: Open Collector vs Push-Pull Output; the NAMUR sensors: Intrinsically Safe Level Switch; the hazardous areas: Hazardous Location Guide for Liquid Level Sensors.)
Four Key Advantages Over Mechanical Float Switches
No Moving Parts, Faster Response, Coating Resistance, and Compact Size
The four advantages table (Featured Snippet):
| Advantage | Mechanical float switch (840/841) | Allen-Bradley solid-state level switch (871A/832/42EF) |
|---|---|---|
| No moving parts | Float, stem, and magnetic contacts all move - wear and failure over time | Fixed sensing element - no mechanical wear, no cycling limit |
| Response time | Dependent on float speed and liquid turbulence - can lag in turbulent conditions | Milliseconds to seconds - the electronic measurement responds instantly to level changes |
| Coating resistance | Low - coating liquids stick to the float and stem and cause jamming and false readings | Higher - capacitive and conductive sensors are less affected; optical sensors are not recommended for coating liquids |
| Compact size | Float and stem require tank space - minimum tank size is determined by the float size | Small probe or electrodes - can fit in tanks as small as 10 mm diameter |
The four advantages of Allen-Bradley solid-state level switches over mechanical float switches are: no moving parts (no mechanical wear and no cycling limit), faster response (electronic measurement reacts instantly to level changes, not to float position), better resistance to coating liquids (fixed sensing elements are less prone to jamming than float stems), and compact size (the sensor body does not scale with tank size): No moving parts: the mechanical float switch has three failure modes that are eliminated by the solid-state design. Float sinking: in heavy liquids or with biofilm buildup, the float can become too heavy to rise reliably, causing the switch to fail in the low position. Stem jamming: coating liquids, suspended solids, and scale can coat the float stem and jam the float. Magnetic contact corrosion: the mechanical contacts inside the float switch can arc, pit, and fail over time, especially when switching inductive loads. None of these failure modes exist in a solid-state switch - the sensing element is fixed, the electronics are potted in epoxy, and the output is a solid-state transistor or relay. Response time: in turbulent liquid conditions (mixing tanks, stirred vessels, tanks with baffles), a float switch responds slowly because the float must physically travel to the new level position and settle before the contacts change state. The settling time can be several seconds. A capacitive or conductive solid-state switch responds in milliseconds - the electronic measurement changes as soon as the liquid dielectric changes at the electrode, regardless of turbulence. Coating resistance: coating liquids (oils with high viscosity, syrups, polymer solutions, liquids with suspended solids) stick to the float stem and eventually jam it. The 871A capacitive sensor is less affected by coating because the capacitive measurement responds to the dielectric change at the electrode surface, not to physical movement. The 832 conductive switch is also resistant because the electrodes are simple rods that are less prone to jamming than a float stem. The 42EF optical switch is not recommended for coating liquids - the prism surface must remain clean for TIR to function. Compact size: a float switch for a 2,000-liter tank requires a float body approximately 50–80 mm in diameter and a stem of the full tank height. A solid-state level switch for the same tank requires only an M18 or M30 threaded probe or a small electrode assembly. The solid-state switch fits in tanks where a float switch would not physically fit, in horizontal mounting configurations, and in tanks with internal obstructions. (The float switch comparison: The Ultimate Guide to Liquid Level Switches; the capacitive: Capacitive Level Sensors Explained; the level switch selection: Choosing the Right Level Switch.)
Five Main Application Areas
Industrial Process, Food and Beverage, Chemical Storage, HVAC, and Power Generation
The five application areas table (Featured Snippet):
| Industry | Allen-Bradley switch used | Application | Key requirement |
|---|---|---|---|
| Industrial process | 871A Capacitive | Level detection in plastic process tanks, sealed tanks, tanks with internal obstructions | Through-wall detection (non-metallic tanks), IP67, chemical compatibility |
| Food and beverage | 42EF PhotoSwitch (optical) | Fill-level detection in bottles and tanks, CIP verification, sanitization monitoring | 3-A, IP69K, FDA-compliant materials, sanitary process connection |
| Chemical storage | 871A Capacitive (PTFE) | Level detection in chemical storage tanks (acids, bases, solvents) | PTFE wetted material, chemical compatibility verification, ATEX for flammable chemicals |
| HVAC | 832 Conductive | Water tank level in boiler feedwater, cooling towers, condensate tanks | Simple, reliable, low cost, grounded metallic tank |
| Power generation | 871A Capacitive or 832 | Level in diesel fuel tanks, coolant tanks, chemical treatment tanks | Wide temperature range, outdoor rating, ATEX for fuel tanks |
The five main application areas for Allen-Bradley solid-state level switches demonstrate the breadth of the portfolio across industrial, sanitary, chemical, HVAC, and power applications - each area demands a different Allen-Bradley switch and a different specification priority: Industrial process: the 871A capacitive switch is the preferred solid-state level switch for industrial process applications - especially in plastic (polypropylene, HDPE) process tanks, sealed tanks where through-wall detection eliminates tank penetration, and tanks with internal agitators, baffles, or other obstructions that prevent float switch installation. The specification priorities are the material compatibility (polypropylene for water-based chemicals; PTFE for aggressive chemicals), the temperature rating (the process temperature must be within the sensor's rating), the enclosure rating (IP67 minimum for process environments), and the output type (PNP for Allen-Bradley and Rockwell Automation PLCs; NPN for third-party PLCs). Food and beverage: the 42EF PhotoSwitch applied to optical level detection is the solid-state choice for food and beverage applications. The glass or sapphire prism is chemically inert, can withstand CIP (clean-in-place) cycles with high-pH and high-temperature cleaning solutions, and is available with 3-A sanitary certification and IP69K washdown rating. Applications include fill-level detection in bottling and canning lines, CIP tank level verification, and sanitization monitoring (is the cleaning solution at the right level?). The specification priorities are the sanitary certification (3-A or EHEDG), the process connection (tri-clamp or DIN 11864 sanitary fitting), the CIP temperature and chemical compatibility, and the response time (fill-level detection on high-speed lines requires millisecond response). Chemical storage: the 871A capacitive switch with PTFE wetted parts is used for level detection in chemical storage tanks - acids, bases, solvents, and other aggressive liquids where a metallic float switch would corrode. The 871A with PTFE electrodes and housing provides chemical resistance across a wide range of liquids. The specification priorities are chemical compatibility (verify every wetted material against the SDS for the specific chemical, concentration, and temperature), the tank material (the 871A can be mounted through a non-metallic tank wall, or the electrodes can be inserted through a metallic tank using a PTFE flange), the ATEX/IECEx certification for flammable and combustible chemicals (specify the gas group and temperature class), and the temperature rating (some chemicals are stored at elevated temperatures). HVAC: the 832 conductive level switch is the solid-state choice for HVAC applications - boiler feedwater tanks, cooling tower basins, condensate receivers, and water makeup tanks. These are metallic, grounded tanks containing conductive water. The 832 is the simplest, most reliable, and lowest-cost option for point-level detection in these applications. Multi-point level detection (high alarm, low alarm, and low-low alarm) is achieved using a single 832 controller with multiple electrode pairs at different heights. The specification priorities are the tank grounding (the 832 requires a grounded metallic tank or a separate ground reference), the electrode material (316SS is standard; PTFE coating is used for high-temperature water), the relay rating (for direct pump or valve control, the relay must be rated for the load), and the enclosure rating (IP65 minimum for indoor mechanical rooms). Power generation: the 871A capacitive or 832 conductive switch is used in power generation applications for level detection in diesel fuel storage tanks (ATEX certified), coolant tanks, and chemical treatment tanks. Diesel fuel is non-conductive (which eliminates the 832) but has a dielectric constant above air (which the 871A can detect). The specification priorities are the wide temperature range (outdoor diesel tanks can range from –40°C to +50°C), the ATEX/IECEx certification for flammable fuel storage (Zone 0 or Zone 1, gas group IIA or IIB), the outdoor enclosure rating (IP67 for weather exposure), and the reliability (power generation facilities require high MTBF and minimal maintenance).
Four Common Mistakes When Selecting Allen-Bradley Solid-State Level Switches
Wrong Technology for the Liquid, Ignoring Tank Material, Specifying the Wrong Output, and Skipping Certification
The four mistakes table (Featured Snippet):
| Mistake | What goes wrong | The fix |
|---|---|---|
| Choosing capacitive for a conductive liquid | The conductive liquid shorts the capacitance measurement - the sensor reads full level at all times | Use the 832 conductive switch for conductive liquids |
| Ignoring the tank material for through-wall capacitive detection | The 871A capacitive switch requires a non-metallic tank wall for through-wall detection - metallic tank walls block the capacitance field | Insert the 871A electrodes through a metallic tank wall using a process penetration; or use a different switch technology |
| Specifying PNP output for an NPN-only PLC | The sensor output is incompatible with the controller input - the system does not work | Verify the PLC input type (sourcing or sinking) before ordering; NPN for European/Asian PLCs; PNP for Allen-Bradley PLCs |
| Skipping the ATEX certification for a hazardous area | Installing a non-certified sensor in a hazardous area is a safety violation and a regulatory violation | Specify the ATEX or IECEx certification for the gas group and temperature class before ordering |
The four common mistakes when selecting Allen-Bradley solid-state level switches are: choosing capacitive (871A) for a conductive liquid (which shorts the measurement), ignoring the tank material requirement for through-wall capacitive detection (which requires a non-metallic tank wall), specifying the wrong output type for the PLC (which creates an incompatible input), and skipping the hazardous area certification (which is a regulatory violation): Wrong technology for the liquid: the most common selection error is choosing the 871A capacitive switch for a conductive liquid (water, aqueous solution, mild acid or base). Conductive liquids conduct electricity between the two capacitive electrodes, which short-circuits the capacitance measurement. The result is a sensor that reads full level regardless of the actual liquid height. The fix: use the 832 conductive switch for conductive liquids. Use the 871A capacitive switch for non-conductive liquids (oils, solvents, hydrocarbons) and for through-wall detection in non-metallic tanks. Ignoring the tank material: the 871A capacitive switch detects level through the tank wall by measuring the capacitance between two electrodes on the outside of the tank. This works only on non-metallic tank walls (plastic, glass, composite) because metallic tank walls are conductive and block the capacitive field. Installing the 871A on a metallic tank wall for through-wall detection results in no detection. The fix: for metallic tanks, insert the 871A electrodes through a process connection penetration into the tank interior. For non-metallic tanks, through-wall mounting is possible. Specifying the wrong output: the 871A and 42EF use solid-state outputs (PNP or NPN). PNP (sourcing) outputs are used with PLCs that have sinking inputs (most Allen-Bradley and Rockwell Automation PLCs). NPN (sinking) outputs are used with PLCs that have sourcing inputs (most European and Asian PLCs). If the wrong output type is ordered, the sensor output is incompatible with the controller input. The fix: verify the controller input type before ordering. Skipping certification: for hazardous area applications (flammable liquids, flammable gases, combustible dusts), the sensor must be ATEX/IECEx certified for the specific gas group and temperature class. Installing a non-certified sensor in a hazardous area is a violation of OSHA, NFPA, and local authority having jurisdiction (AHJ) regulations, and it creates an explosion hazard. The fix: specify the required ATEX or IECEx certification (gas group, temperature class, and zone) before selecting the model number. (The selection guide: Choosing the Right Level Switch; the level switch guide: The Ultimate Guide to Liquid Level Switches; the hazardous areas: Hazardous Location Guide for Liquid Level Sensors.)
Five Factors for Matching the Right Allen-Bradley Solid-State Level Switch
The Decision Tree - Liquid First, Then Tank, Then Environment, Then Output, Then Price
The five factors table (Featured Snippet):
| Factor | Decision | Resulting Allen-Bradley switch |
|---|---|---|
| 1. Liquid electrical properties | Conductive liquid (water, aqueous) → use conductive; non-conductive liquid (oil, solvent) or non-metallic tank → use capacitive; clean liquid, sanitary → use optical | 832 for conductive; 871A for non-conductive/non-metallic; 42EF for sanitary optical |
| 2. Tank material | Non-metallic (plastic, glass, composite) → capacitive through-wall possible; metallic → insert electrode through penetration or use conductive | 871A through-wall on non-metallic; 871A insertion or 832 on metallic |
| 3. Environment | Hazardous area → specify ATEX/IECEx; washdown → specify IP69K; wide temperature → verify temperature rating | ATEX-certified 871A for hazardous; IP69K 42EF for washdown; verify temperature for outdoor applications |
| 4. Output type | Allen-Bradley PLC → PNP output; third-party PLC → verify input type (NPN or PNP) | PNP for Allen-Bradley PLCs; verify for others |
| 5. Price and availability | Standard price and 24–48 hour delivery from authorized distributor; lead time for ATEX-certified models may be longer | Use authorized Rockwell Automation distributor for fastest delivery and full warranty |
The five factors for matching the right Allen-Bradley solid-state level switch to the application are answered in this order: what is the liquid (conductive or non-conductive - this determines the technology family), what is the tank made of (metallic or non-metallic - this determines whether through-wall detection is possible), what is the environment (hazardous area, washdown, outdoor - this determines the certification and the enclosure rating), what is the controller input (PNP or NPN - this determines the output type), and what is the price and availability (this determines the source): Factor 1 - Liquid: the liquid's electrical properties are the primary selection filter. If the liquid is conductive (water, aqueous solutions, mild acids and bases), the 832 conductive level switch is the technology choice. If the liquid is non-conductive (oils, solvents, hydrocarbons) or the tank is non-metallic, the 871A capacitive switch is the technology choice. If the liquid is clean (no coating, no solids) and the application is sanitary (food, beverage, pharmaceutical), the 42EF optical switch is the technology choice. Factor 2 - Tank material: for non-metallic tanks (plastic, glass, composite), the 871A can be mounted on the outside of the tank for through-wall detection. This eliminates tank penetration, preserves the tank seal, and simplifies installation. For metallic tanks, the electrodes must be inserted through a process connection penetration into the tank interior. The 832 conductive switch requires a grounded metallic tank or a separate ground reference. Factor 3 - Environment: hazardous area certification (ATEX/IECEx) is available for the 871A in specific model numbers designed for gas and dust environments. Specify the zone (0, 1, or 2), the gas group (IIA, IIB, or IIC), and the temperature class (T1–T6) before ordering. For food and beverage washdown applications, specify the 42EF with IP69K rating and 3-A sanitary certification. For outdoor applications, verify the temperature range and the UV resistance of the housing material. Factor 4 - Output: verify the PLC input type before ordering. Allen-Bradley PLCs (1734 POINT I/O, 5069 CompactLogix) use PNP (sourcing) inputs. Most third-party PLCs (Siemens, Schneider, Mitsubishi) use NPN (sinking) inputs. The output type is selected at the model number level - it cannot be changed in the field. Factor 5 - Price and availability: Allen-Bradley sensors and switches are sourced through the Rockwell Automation authorized distributor network (over 4,000 distributors globally). Standard models are typically available within 24–48 hours from a local distributor. ATEX-certified models, special materials (PTFE), and non-standard process connections may have longer lead times. Always verify availability and lead time for the specific model number before specifying it in a project. (The selection guide: Level Sensor Switch Selection Guide; the level switch guide: Choosing the Right Level Switch; the Allen-Bradley overview: Sensors and Switches: Allen-Bradley.)
FAQ
Q1: What is a solid-state level switch?
A solid-state level switch is a level switch that detects the presence of a liquid or material without a moving float or mechanical contact. Allen-Bradley solid-state level switches include three types: the 871A capacitive switch (measures the change in capacitance between two electrodes as liquid replaces air), the 832 conductive switch (measures the current flow between electrodes immersed in a conductive liquid), and the 42EF PhotoSwitch applied to optical level detection (detects liquid at a prism tip by the change in total internal reflection of infrared light). All three have no moving parts in the sensing element, which makes them more reliable, faster, and more resistant to coating and mechanical wear than mechanical float switches.
Q2: What is the difference between the Allen-Bradley 871A and 832 level switches?
The 871A capacitive switch detects level by measuring capacitance - it works in both conductive and non-conductive liquids and can detect level through a non-metallic tank wall. The 832 conductive switch detects level by measuring current flow between electrodes - it only works in conductive liquids (water, aqueous solutions, mild acids and bases) and requires a grounded metallic tank or a ground reference. Use the 871A for non-metallic tanks, non-conductive liquids (oils, solvents), and through-wall detection. Use the 832 for conductive liquids in grounded metallic tanks where the simplest and lowest-cost solution is required.
Q3: Can the Allen-Bradley 871A capacitive switch detect level through a metallic tank?
No - the 871A capacitive switch cannot detect level through a metallic tank wall because metallic tank walls are electrically conductive and block the capacitive field between the sensor electrodes. For metallic tanks, the 871A electrodes must be inserted through a process connection penetration into the tank interior, where they measure capacitance between the electrodes inside the tank. Alternatively, the 832 conductive switch (for conductive liquids) or a float switch (series 840) can be used in metallic tanks.
Q4: When should I use the Allen-Bradley 42EF PhotoSwitch for level detection instead of the 871A?
Use the 42EF PhotoSwitch for level detection when the application is a clean liquid in a sanitary or food and beverage environment, when fast response (1–10 ms) is required, when a very small sensor body is needed (M18 or smaller), or when the liquid is non-conductive and a capacitive sensor is not suitable. Avoid the 42EF for coating liquids, for liquids that leave residue on the prism surface, for foam-heavy applications, and for non-sanitary industrial process applications where the capacitive 871A is the more robust choice.
Q5: Are Allen-Bradley solid-state level switches compatible with non-Allen-Bradley PLCs?
Yes - Allen-Bradley solid-state level switches (871A and 42EF) with PNP or NPN outputs are universally compatible with any PLC or controller that accepts a 24 VDC digital input, regardless of the PLC manufacturer. PNP outputs require a sinking input on the PLC. NPN outputs require a sourcing input. The 832 conductive switch, with its relay contact output, is compatible with any PLC input (AC or DC) that accepts a dry contact. Verify the input type of the non-Allen-Bradley PLC before selecting the output type of the switch.
The Bottom Line
Allen-Bradley solid-state level switches - the 871A capacitive switch for non-metallic tanks and non-conductive liquids, the 832 conductive switch for conductive liquids in grounded metallic tanks, and the 42EF PhotoSwitch optical switch for clean sanitary applications - are the reliable, long-life alternative to mechanical float switches in demanding level detection applications where coating liquids, small tanks, sealed vessels, or fast response times prevent the float switch from working reliably. The three solid-state families are chosen by answering five questions in order: what is the liquid (conductive or non-conductive - this selects the technology), what is the tank made of (metallic or non-metallic - this determines the installation method), what is the environment (hazardous area, washdown, outdoor - this selects the certification and the enclosure rating), what is the controller input (PNP or NPN - this selects the output type), and what is the delivery requirement (this selects the source and the lead time). The four advantages over float switches - no moving parts, faster response, coating resistance, and compact size - make the solid-state switch the correct choice for any application where the mechanical float would fail. The four common mistakes - capacitive in conductive liquid, through-wall on metallic tank, wrong output type, and missing certification - are avoided by answering the five questions in the correct order. The one-sentence rule: the right Allen-Bradley solid-state level switch is chosen by matching the liquid's electrical properties to the technology (conductive → 832; non-conductive or non-metallic tank → 871A; clean sanitary → 42EF), then matching the environment to the certification and enclosure rating, then matching the output to the controller, and sourcing from an authorized Rockwell Automation distributor. (The Allen-Bradley brand overview: Sensors and Switches: Allen-Bradley; the level switch guide: The Ultimate Guide to Liquid Level Switches; the level switch selection: Choosing the Right Level Switch; the level sensor selection: Level Sensor Switch Selection Guide; the capacitive sensors: Capacitive Level Sensors Explained; the hazardous areas: Hazardous Location Guide for Liquid Level Sensors.)
Last updated: August 2026
Disclaimer: This article is an educational guide to Allen-Bradley solid-state level switches for general reference. The product series, specifications, and application information reflect common knowledge of the Allen-Bradley product range under Rockwell Automation; individual models vary by series, version, and manufacturer datasheet. The selection criteria, the application areas, and the comparison with mechanical float switches are general engineering guidance and do not constitute a recommendation for any specific Allen-Bradley product, Rockwell Automation product, or competing brand. Always verify the specific model's data sheet, voltage rating, output type, sensitivity range, wetted materials, chemical compatibility, temperature and pressure ratings, process connection, certifications, and environmental ratings with the manufacturer's documentation and the applicable standards and codes (ATEX, IECEx, NFPA, OSHA, 3-A, EHEDG, FDA) before selection and installation. Selection and installation must be performed by qualified personnel. Allen-Bradley, PhotoSwitch, and SensaGuard are registered trademarks of Rockwell Automation, Inc.