Introduction
Important: Specific product specifications, model numbers, accuracy ratings, and configuration procedures vary by sensor model and software version. Always consult the official Onset HOBOnet product datasheets and HOBOware software documentation for authoritative specifications. This guide uses representative figures from typical HOBOnet-compatible sensors to illustrate system principles.
System Architecture
Network Overview
Three-layer architecture:
Layer 1 - Sensors
[Water level sensor] [Rain gauge] [Temp] [Conductivity] ...
| | | |
Layer 2 - Remote Logger Station (Gateway)
+-----------------------------------------------------+
| RX3000 / RX2100 / RX3004 (Onset remote station) |
| -接收多传感器数据 (accepts multiple sensors) |
| -记录并存储本地数据 |
| -通过 WiFi / Cellular / Ethernet 上传至云端 |
+-----------------------------------------------------+
|
Layer 3 - Cloud Platform
HOBOlink web dashboard / HOBOware Pro / third-party API
Remote Logger Stations
Feature RX3000 RX2100 RX3004
Network options WiFi / Ethernet WiFi / Ethernet Cellular + WiFi backup
Sensor ports 2 smart sensor ports 1 smart sensor port 4 smart sensor ports
Display Built-in LCD Built-in LCD Built-in LCD
Power AC adapter + backup battery AC adapter + backup battery AC adapter + solar + backup battery
Primary use Indoor, WiFi coverage Indoor, compact Outdoor, remote, cellular
Communication Options
Method Range Best For Notes
WiFi (802.11b/g/n) Local network only Indoor facilities, campuses with WiFi No ongoing data costs
Ethernet (RJ45) Local network Buildings with wired network Reliable, no range limit within LAN
Cellular 4G/LTE (RX3004) Anywhere with coverage Remote sites, field deployment Requires SIM; data plan needed
Satellite (external modem) Global Remote sites, no cell coverage Higher cost; satellite data plan required
Compatible Sensors for Water Level Monitoring
Ultrasonic Level Sensors
Key parameters:
Range: typically 0.2-5 m or 0.5-10 m (check specific model datasheet)
Accuracy: typically +/- 1-3 mm (check specific model datasheet)
Output: 4-20 mA (current loop) or digital (SDI-12)
Beam angle: typically 8-12 degrees
Operating temp: -20 to +60 C (varies by model)
Submersible Pressure Sensors
Key parameters:
Range: 0-1 m WC to 0-100 m WC (select to match well/wetland depth)
Accuracy: typically +/- 0.1-0.5% FS (check specific model datasheet)
Output: 4-20 mA two-wire current loop
Vent tube: vented to atmosphere (for absolute depth measurement)
Cable length: typically up to 500 m (check specific model)
Float Switches and Point-Level Sensors
Conductivity Sensors
Rain Gauges and Environmental Sensors
System Configuration and Deployment
Site Survey and Sensor Placement
Factor Consideration
Access and safety Can the site be accessed in all weather conditions, including during floods? Is specialised access equipment required?
Power availability Is AC power available? Is solar radiation adequate for a solar panel? What is the solar aspect (south-facing in northern hemisphere)?
Network coverage Is WiFi or cellular coverage available? Conduct a site survey with a mobile phone or signal strength meter.
Sensor mounting Is there an existing structure to mount an ultrasonic sensor? Can a pressure sensor be lowered safely into the well or borehole?
Flood risk Is the logger station protected from floodwater? Can the sensor survive submersion?
Lightning Is the site in an area of high lightning risk? Is surge protection required for the sensor cable?
Mounting the Ultrasonic Sensor
Mounting checklist:
●Mount above highest water level: observe the beam angle specification - at the maximum water level, the entire beam must still hit water, not the tank wall or overflow
●Aim at the centre: in tanks, aim at the geometric centre. In open channels or streams, aim at a point with an unobstructed path to the water surface
●Protect from direct weather: use a radiation shield for the sensor body if it is exposed to direct sunlight - solar heating of the housing causes measurement drift
●Stilling well: in turbulent conditions, a 50-100 mm diameter PVC pipe provides a calm surface for the ultrasonic beam to measure
●Cable routing: route the sensor cable upward from the transducer to form a drip loop before it connects to the logger - this prevents water running down the cable into the connector
Configuring the Remote Logger
●Logging interval: the frequency at which the station records a sensor reading. Typical intervals range from 1 minute (real-time monitoring) to 60 minutes (long-term trend monitoring with minimal data volume). Battery life decreases with shorter intervals.
●Transmission interval: how often the station uploads logged data to the cloud. This can be set independently of the logging interval - the station stores data locally and transmits in batches to conserve cellular data.
●Alarm thresholds: configure high and low level alarms that trigger email or SMS notifications when the sensor reading crosses the threshold. Alarms can be set for immediate delivery or for sustained conditions (e.g., level above threshold for more than 15 minutes to avoid nuisance alarms from transient spikes).
●Data export settings: configure automatic data export to third-party platforms via API or webhook if the on-platform visualisation tools do not meet the project requirements.
Data Management and Platform Integration
HOBOlink Cloud Platform
Feature Description
Real-time dashboards Live readings from all sensors in the network, displayed as gauges, charts, and maps
Historical data Access to the full time-series record for any sensor, at any logging interval, with date range selection
Alarm management Configure alarm rules, receive email or SMS notifications, acknowledge and annotate alarm events
Data export Export data as CSV, Excel, or PDF reports. Configure automated scheduled exports to email or cloud storage
Multi-site management Manage multiple remote stations from a single dashboard, useful for organisations operating many locations
User access control Define roles and permissions for different users - operators, managers, auditors - with appropriate access levels
Third-Party Integration
●SCADA and ICS platforms: operational data from HOBOnet sensors feeding into SCADA for alarm management and process control
●Environmental databases: standardised data formats (e.g., WQP, WaterML) for submission to regulatory agencies
●Geographic information systems (GIS): spatial data from multiple monitoring sites overlaid on maps for watershed-scale analysis
●Business intelligence tools: dashboards in Power BI, Tableau, or custom web applications built on exported or API-sourced HOBOnet data
●Flood forecasting models: real-time water level data feeds into hydrological models that predict flood risk and trigger early warning systems
Applications
River and Stream Gauging
Groundwater and Borehole Monitoring
Agricultural Irrigation Monitoring
Environmental Research
Troubleshooting and Maintenance
Common Issues
Issue Likely Cause Resolution
No data transmitted Cellular/WiFi coverage lost Check antenna connection; relocate gateway or add signal booster
No data transmitted SIM card issue (cellular) Verify SIM is active and data plan is paid
Level reading stuck at one value Sensor beam blocked Remove obstruction; check for debris, spider webs, ice on sensor face
Level reading drifting Sensor face dirty or biofouled Clean sensor face; in biological environments consider anti-fouling housing
Level reading inaccurate Sensor calibration drift Perform two-point calibration against staff gauge or dip meter reference
Battery depleting quickly Logging interval too short Increase logging interval; add solar panel if cellular transmission is frequent
Spurious high readings Ultrasonic echo from tank wall Relocate sensor; use narrower beam angle model; add stilling well
Data gap in records Network outage Remote station retains data locally; data recovered when connection restored
Maintenance Schedule
Task Frequency Notes
Clean ultrasonic sensor face Every 3-6 months Remove algae, insects, dust, ice from transducer
Check mounting and alignment Every 6 months Verify sensor is level and aimed at water centre
Inspect cable and connectors Every 6 months Check for damage, moisture ingress, loose connections
Download and verify data Every 1-3 months Check for gaps, drift, or sensor faults
Test alarm notifications Every 6 months Simulate alarm condition to confirm email/SMS delivery
Replace batteries Every 1-3 years Dependent on logging interval and transmission frequency; use solar where possible
Recalibrate against reference Every 12 months Compare sensor reading to staff gauge or dip meter
Conclusion